Histopathology Equipment
Sub Categories
Download Catalog
Note: To download a single product catalog please goto the product page and download catalog

HTP11-100A
Automatic Cryostat Microtome
| Refrigerating range to set | room temperature ~ - 60 ℃ |
| Section thickness | 0 ~100 μm |
| Minimum division value | 0.5 μm |
| Trimming range | 0 ~ 600 μm |

HTP11-45S
Semi Automatic Cryostat
| Security type | l category ,B type |
| Voltage frequency | AC 220 V , 50 Hz (± 10 % ) Or AC 110 V , 60 Hz (± 10 % ) |
| Input power | 650 VA |
| Range of temperature setting | ﹣35 ℃ to ﹣10 ℃ |

HTP11-60S
Semi Automatic Cryostat
| Freezing chamber temperature range | - 40 ℃ ~ -10 ℃ |
| Freezing shelf minimum temperature | - 45 ℃ |
| Chuck holder minimum temperature | - 50 ℃ |
| Minimum temperature of Peltier element on freezing shelf | - 60 ℃ |

HTP21-100S
Semi Automatic Microtome
| Slice thickness range | 0.5 μm ~ 100 μm (3 ~ 5 um is the best slicing effect) |
| Section thickness setting | 0.5 ~ 5 μm,in 0.5 μm increment |
| Section thickness setting | 5 ~ 20 μm,in 1 μm increments |
| Section thickness setting | 20 ~ 60 μm, in 5 μm increments |

HTP21-300V
Vibrating Microtome
| Speed of Specimen Sectioning | 0-1.3 mm/s(adjustable) |
| Vibrating range | 0 ~ 1 mm |
| Lifting range of specimen platform | 20 mm |
| Section thickness setting range | 10-300 um |

HTP21-600A
Fully Automatic Microtome
| Section thickness range 0.5μm~100μm (3~5um is the best slicing effect) | 0.5 μm ~ 100 μm (3 ~ 5um is the best slicing effect) |
| Section thickness setting | 0.5 ~ 5 μm, in 0.5 μm increment |
| Section thickness setting | 5~20 μm,in 1 μm increments |
| Section thickness setting | 20 ~ 60 μm,in 5 μm increments |

HTP21-60R
Rotary Microtome
| Slice thickness range | 0 μm~60 μm |
| Section thickness setting | 0-2 μm in 0.5 μm – increments |
| Section thickness setting | 2-10 um in 1 um – increments |
| Section thickness setting | 10-20 um in 2 um – increments |

HTP31-100
Tissue Processor
| Capacity | 100 cassettes 130kg |
| Nominal voltage | AC220V |
| Nominal frequency | 60 Hz |
| Main fuses | 10 A |

HTP31-10A
Automatic Tissue Processor
| Tanks | 12 Tanks (3 wax cylinders in the end) |
| Capacity of single- tanks | 1000 ml |
| Basket can hold | 60 specimens |
| Single tanks processing time | set arbitrarily in the range of 0 to 99 hour(s) |

HTP31-12S
Spin Tissue Processor
| Steps of processing tissue | 12 steps |
| Glass container | Quantity — 9 capacity – 1.2 L |
| Wax cup | Quantity — 3capacity — 1L. |
| Temperature range | 60-99 ℃ (can be designed according to user requirements) |

HTP31-15A
Automatic Tissue Processor
| Tanks | 12 Tanks (3 wax Tanks in the end) |
| Capacity of single tank | 1500 ml |
| Basket can hold | 75 specimens |
| Single-tanks processing time | Randomly set within the range from 0 to 99 hour(s). |

HTP31-200
Tissue Processor
| Capacity | 200 cassettes 165kg |
| Nominal voltage | AC220V |
| Nominal frequency | 60 Hz |
| Main fuses | 10 A |

HTP31-20D
Double Basket Tissue Processor
| Volume of individual reagent containers | 2000 ml |
| Number of reagent containers | 14 |
| Hanging basket filtrate | Time can be adjusted arbitrarily |
| Number of dehydrated tissues | More than 200 |

HTP31-22A
Automatic Tissue Processor
| Liquid cylinders | 12 (3 of which are wax cylinders) |
| Single cylinder volume | 2200 ml |
| Drip retention time | adjustable from 5 to 999 seconds |
| Single cylinder working time | arbitrarily set within 0 - 24 hours |

HTP31-300
Tissue Processor
| Capacity | 300 cassettes 172kg |
| Nominal voltage | AC220V |
| Nominal frequency | 60 Hz |
| Main fuses | 10 A |

HTP31-60S
Spin Vacuum Tissue Processor
| Option | 2 basket loading |
| Capacity | 2.3 L for reagent container, 1.8 L for wax parafin container |
| Temperature of wax container | 60-99 ℃ |
| Battery backup | 4 hours (Optional) |

HTP41-12
Hybridizer
| Temperature control range | RT + 5 ℃ ~ 100 ℃ |
| Temperature set range | 0 ℃ ~ 100 ℃ |
| Accuracy of temperature | ≤ ± 1 ℃ |
| Uniformity temperature | ≤ ± 1 ℃ |

HTP41-15
Slide Stainer
| First cylinder | provides starting protection |
| Cleaning cylinder | 5 |
| Hematoxylin cylinder | 1 |
| Differentiation cylinder | 1 |

HTP41-16
Slide Stainer
| Programs | 16 sets can be programmed arbitrarily |
| Volume of a single cylinder | 1000 ml |
| Loading capacity of a single cylinder | 62 pieces each time |
| Single-cylinder processing time | 0~99 min 99 s |

HTP41-30
Fully Immuno Autosatiner
| Staining mode | Single staining |
| Reagent consumption | General use 120 μl |
| Reagent positions | 36 (29 for antibody reagent bottles, 7 for detection system bottles) |
| Self-calibration | When opening the instrument, it will run self-calibration automatically |

HTP41-30A
Automatic Slide Stainer
| Specimen slide throughput | At least 200 specimen slides per hour (depend on the selected program) |
| Loading capacity | 3 slides rack |
| Slide rack capacity | 30 specimen slides |
| Total number of stations | 26 |

HTP41-48
Immuno Autostainer
| Slides Capacity | 48 |
| Reagents Capacity | 64 |
| Minimum dropping reagent | 50 μl |
| Dropping reagent increment | 50 μl, 100 μl, 150 μl, 200 μl |

HTP41-75A
Automatic Slide Stainer
| Screen | 7 – inch color touch screen operation |
| Cylinder design reagents | 18 |
| Dye cylinder volume | 1000 ml |
| Rated voltage | 220 v ± 10 % AC |

HTP51-100
Pathological Slide Scanner
| Resolution | 10000x10000 DPI |
| Dynamic range | 3.8 OD |
| Scan area | 24.3x36.5 mm |
| Scanning medium | 75x25 mm section |

HTP51-15
Mini Cover Sliper
| Slide seat | 15 |
| Speed | 30 tablets/min |
| Rated voltage | AV 220 V ± 10 % |
| Power frequency | 50 ± 1 Hz |

HTP51-150
Slide Printer
| Capacity | 150 Slides |
| Average printing speed | ≤ 3S / slide |
| Printing accuracy | ≥ 1250 pi |
| Maximum Capacity | ≥ 150 slides |

HTP51-200
Cover Sliper
| Specimen slide throughput | 200 ~ 400 pieces/hour |
| Specimen slide holders | 20 ~ 30 pieces/holder |
| Output magazines | 30 piece/magazine |
| Cover slip magazine capacity | 120 ~ 160 pieces/magazine |

HTP51-500
Digital Pathological Slide Scanner
| Short Desc | 5 Slides Digital Pathological Slide Scanner |
| Acceptable Slides | 1inx3in / 2inx3in |
| Capacity | 5 slides (150-500 slides per day) |
| Lighting | LED |

HTP51-75
Cassette Printer
| Pringting method | Cassette Laser Printing |
| Average printing speed | ≤ 3S / Cassette |
| Printing accuracy | ≥ 1250 pi |
| Maximum Capacity | ≥ 75 Cassettes |

HTP61-100
Paraffin Dispenser
| Range of temperature | Ambient~100 ℃ |
| Precision | ± 1 % |
| Voltage | AC 220 V 50 Hz |
| Voltage | AC 110 V 60 Hz |

HTP61-220
Tissue Baking Processor
| Range of setting temperature | Ambient to 90 °C (constant adjusting). |
| Temperature precise error | + 2 °C. |
| Allowance ambient temperature | 0 – 40 °C |
| Working voltage | 220 V / 50 Hz |

HTP61-25
Tissue Floating Water Bath
| Capacity | 2.5 L |
| Temperature range | RT to 75 ˚ C |
| Outside Size | 270x210 mm (D)x(H) |
| Interior Size | 210x65 mm (D)x(H) |

HTP61-30
Tissue Flotation Workstation
| Dimension | 510×340×220 mm (WxDxH) |
| Dimension of Water Bath | 190×140×70 mm (WxDxH) |
| Temperature control range | Three parts all adjustable from 30 – 90 ℃, automatic constant temperature |

HTP61-600
Tissue Embedding System
| Main Console Nominal supply voltage | 220 V / 50 Hz or 110 V / 60 Hz |
| Main Console Maximum power draw | 600-800 W |
| Main Console Working temperature | Ambient to 99℃ |
| Main Console Increments | 1 centigrade |

HTP61-75
Paraffin Trimmer
| Working area dimension | 150x220 mm |
| Temperature range | Ambient to 75 ℃ |
| Temperature control accuracy | ± 1 ℃ |
| Supply voltage | 220 V ± 10 % 50 / 60 Hz OR 110 V ± 10 % 50 / 60 Hz |

HTP61-800
Tissue Embedding System
| Main Console Nominal supply voltage | 220 V / 50 Hz |
| Main Console Maximum power draw | 800-1000 W |
| Main Console Working temperature | From ambient to 99 ℃ increments 1 ℃ |
| Main Console Capacity Paraffin reservoir | 6.0 Lt |

HTP61-90
Tissue Water Bath
| Range of setting temperature | Ambient to 90 °C (constant adjusting) |
| Temperature precise error | + 2 °C |
| Allowance ambient temperature | 0 – 40 °C |
| Working voltage | 220 V / 50 Hz |