Meters
Sub Categories
Download Catalog
Note: To download a single product catalog please goto the product page and download catalog
- pH Meter
- pH/Ion Meter
- Turbidity Meter
- DO Meter
- Conductivity Meter
- Colorimeter
- Thermal Imaging Camera Meters
- Multi-parameter Analyzer
- Gloss Meter
- Haze Meter
Download Manuals

MET101-054
Multi-parameter Analyzer
| DC Voltage: 300 mV | ± (0.1%+5) |
| DC Voltage: 3 V/30 V/300 V | ± (0.05%+5) |
| DC Voltage: 1000 V | ± (0.1%+5) |
| DC Current: 300 µA/3 mA/30 mA/300 mA | ± (0.5%+10) |

MET101-074
Multi-parameter Analyzer
| DC Voltage: 200 mV/2 V/20 V/200 V | ± (0.5%+2) |
| DC Voltage: 600 V | ± (0.8%+2) |
| AC Voltage: 2 V/20 V/200 V | ± (1.0%+3) |
| AC Voltage: 600 V | ± (1.2%+3) |

MET101-078
Multi-parameter Analyzer
| DC Voltage: 60 Mv/600 mV/6 V/60 V | ± (0.5%+3) |
| DC Voltage: 600 V | ± (0.5%+3) |
| AC Voltage: 60 mV/600 mV/6 V/60 V/600 V | ± (0.8%+3) |
| DC Current: 600 µA/6 mA/60 mA/600 mA | ± (0.8%+3) |

MET101-083
Multi-parameter Analyzer
| DC Voltage: 6 V/60 V/600 V | ± (0.8%+3) |
| AC Voltage: 60 Mv/600 mV/6 V/60 V/600 V/750 V | ± (0.8%+3) |
| DC Current: 600 mA | ± (1.0%+3) |
| AC Current: 600 mA | ± (1.5%+3) |

MET101-100
Multi-parameter Analyzer
| DC Voltage: 600 mV/6 V/60 V/600 V/1000 V | ± (0.5%+3) |
| AC Voltage: 6 V/60 V | ± (0.8%+3) |
| AC Voltage: 600 V/750 V | ± (1%+10) |
| DC Current: 60 µA/600 µA/6 mA/60 mA/600 mA | ± (0.8%+3) |

MET101-130
Multi-parameter Analyzer
| DC Voltage: 200 mV/2 V/20 V/200 V | ± (0.5%+3) |
| DC Voltage: 600 V | ± (0.8%+5) |
| AC Voltage: 200 V/600 V | ± (0.8%+3) |
| AC Voltage: 600 V | ± (1.0%+5) |

MET101-148
Multi-parameter Analyzer
| DC Voltage: 200 mV/2 V/20 V/200 V | ± (0.5%+2) |
| DC Voltage: 600 V | ± (0.8%+2) |
| AC Voltage: 2 V/20 V/200 V | ± (1.2%+10) |
| DC Current: 200 µA/2 mA/20 mA | ± (1.0%+2) |

MET101-166
Multi-parameter Analyzer
| DC Voltage: 400 Mv/4 V/40 V/400 V | ± (0.8%+2) |
| DC Voltage: 600 V | ± (0.1%+2) |
| AC Voltage: 40 V/400 V/600 V | ± (1.2%+10) |
| DC Current: 400 µA/4 mA/40 mA/400 mA | ± (0.1%+2) |

MET101-169
Multi-parameter Analyzer
| DC Voltage: 6 V/60 V/600 V | ± (0.8%+3) |
| AC Voltage: 60 mV/600 mV/6 V/60 V/600 V/750 V | ± (0.8%+3) |
| Resistance: 6 kΩ/60 kΩ/600 kΩ | ± (1.0%+3) |
| Resistance: 6 MΩ/10 MΩ | ± (1.2%+5) |

MET101-194
Multi-parameter Analyzer
| DC Voltage: 60 mV/600 mV/6 V/60 V/600 V/1000 V | ± (0.7%+2) |
| AC Voltage: 60 mV/600 mV/6 V/60 V/600 V/750 V | ± (0.8%+3) |
| DC Current: 600 µA/6000 µA/60 MA/600 mA | ± (1.2%+3) |
| DC Current: 6 A/10 A | ± (2.0%+10) |

MET101-200
Multi-parameter Analyzer
| DC Voltage: 2 V/20 V/200 V | ± (0.5%+3) |
| DC Voltage: 600 V | ± (0.8%+5) |
| AC Voltage: 2 V/20 V/200 V | ± (0.8%+3) |
| AC Voltage: 600 V | ± (1.0%+5) |

MET101-600
Multi-parameter Analyzer
| DC Voltage: 600 mV/6 V/60 V/600 V/1000 V | ± (0.5%+3) |
| AC Voltage: 6 V/60 V | ± (0.8%+3) |
| AC Voltage: 600 V/750 V | ± (1.0%+10) |
| DC Current: 60 µA/60 mA/600 mA | ± (0.8%+3) |

MET101-750
Multi-parameter Analyzer
| DC Voltage: 600 mV/6 V/60 V/600 V/1000 V | ± (0.5%+3) |
| AC Voltage: 6 V/60 V | ± (0.8%+3) |
| AC Voltage: 600 V/750 V | ± (1.0%+10) |
| DC Current: 60 µA/60 mA/600 mA | ± (0.8%+3) |

MET102-154
Haze Meter
| Optical Geometry | Transmittance: 0/D ( 0-degree viewing angle diffuse illumination) |
| Standards compliant | ASTM D1003/1044,ISO 13468,ISO 14782,GB/T 2410, JJF 1303-2011,CIE 15.2,GB/T 3978,ASTM E308,JIS K7105,JIS K7361,JIS K 7136 |
| Integrating Sphere Size | Φ 154mm |
| Illuminant | 400 ~ 700 nm combined LED light source (wavelength extended is customized) |

MET102-154C
Haze Meter
| Optical Geometry | Transmittance: 0/D ( 0-degree viewing angle diffuse illumination) |
| Standards compliant | ASTM D1003/1044,ISO 13468,ISO 14782,GB/T 2410, JJF 1303-2011,CIE 15.2,GB/T 3978,ASTM E308,JIS K7105,JIS K7361,JIS K 7136 |
| Integrating Sphere Size | Φ 154mm |
| Illuminant | 400 ~ 700 nm combined LED light source (wavelength extended is customized) |

MET102-700C
Haze Meter
| Optical Geometry | Transmittance: 0/D (parallel illumination, diffuse reflection receiving) |
| Standards compliant | ASTM D1003/1044, ISO 13468, ISO 14782, GB/T 2410, JJF 1303-2011, CIE 15.2, GB/T 3978, ASTM E308, JIS K7105, JIS K7361, JIS K 7136 |
| Integrating Sphere Size | Φ154mm |
| Illuminant | 400-700nm combined LED lamp (wavelength can be customized) |

MET103-100
Haze Meter
| Optical Geometry | Transmittance: 0/D ( 0-degree viewing angle diffuse illumination) |
| Standards compliant | ASTM D1003/1044,ISO 13468,ISO 14782,GB/T 2410,JJF 1303-2011,CIE 15.2,JIS K7105,JIS K7361,JIS K 7136 |
| Integrating Sphere Size | Φ 154mm |
| Illuminant | 400 ~ 700 nm combined LED light source |

MET103-700
Haze Meter
| Optical Geometry | Transmittance: 0/D (parallel illumination, diffuse reflection receiving) |
| Standards compliant | ASTM D1003/1044,ISO 13468,ISO 14782,GB/T 2410,JJF 1303-2011,CIE 15.2,JIS K7105,JIS K7361,JIS K 7136 |
| Integrating Sphere Size | Φ154mm |
| Illuminant | 400-700nm combined LED lamp |

MET103-700A
Haze Meter
| Optical Geometry | Transmittance:0/D Parallel light illumination, diffuse reflection reception |
| Features | Double caliber compensation port |
| Standards compliant | ASTM D1003/1044, ISO 14782,GB/T 2410, JJF 1303-2011,CIE 15.2,JIS K7105,JIS K7361,JIS K 7136 |
| Integrating Sphere Size | Φ 40mm |

MET103-700B
Haze Meter
| Optical Geometry | Transmittance:0/D Parallel light illumination, diffuse reflection reception |
| Features | Photoelectric integration, No compensation port |
| Standards compliant | ASTM D1003/1044, ISO 14782,GB/T 2410, JJF 1303-2011,CIE 15.2,JIS K7105,JIS K7361,JIS K 7136 |
| Integrating Sphere Size | Φ 40mm |

MET103-700C
Haze Meter
| Optical Geometry | Transmittance:0/D Parallel light illumination, diffuse reflection reception |
| Features | Photoelectric integration, No compensation port |
| Standards compliant | ASTM D1003/1044,GB/T 2410,JJF 1303-2011,CIE 15.2,JIS K7105,JIS K7361,JIS K 7136 |
| Integrating Sphere Size | Φ 40mm |

MET11-07
Thermal Imaging Camera Meters
| Display screen | 3.2 "full angle TFT/display screen |
| Infrared image resolution | 220x160 |
| visible image resolution | 300,000 pixel |
| Field angle/shortest focus length | 27°x35°/0.15 m |

MET11-14
Thermal Imaging Camera Meters
| Display screen | 3.5 "full angle TFT display screen |
| Infrared image resolution | 320x240 |
| visible image resolution | 300,000 pixel |
| Field angle/shortest focus length | 56°x 42°/ 0.15 m |

MET11-15
Thermal Imaging Camera Meters
| Display | 2.4 " Color display |
| Resolution | 60x60 |
| Total pixels | 3600 |
| FOV/Shortest focal length | 20°x20°/0.5 m |

MET21-02
pH Meter
| pH: Range | -2.00 to 14.00 pH |
| pH: Resolution | 0.01 pH |
| pH: Accuracy | ± 0.01 pH |
| pH: Calibration Points | Up to 2 |

MET21-05
pH Meter
| pH: Range | -2.00 to 20.00 pH |
| pH: Resolution | 0.1, 0.01 pH |
| pH: Accuracy | ± 0.02 pH |
| pH: Calibration Points | Up to 5 |

MET21-06
pH Meter
| pH: Range | -2.000 to 20.000 pH |
| pH: Resolution | 0.1, 0.01, 0.001pH |
| pH: Accuracy | ± 0.002 pH |
| pH: Calibration Points | Up to 6 |

MET21-08
pH Meter
| pH: Range | -3.00 to 20.00 pH |
| pH: Resolution | 0.1, 0.01, 0.001pH |
| pH: Accuracy | ± 0.002 pH |
| pH: Calibration Points | Up to 8 |

MET21-14
pH Meter
| pH: Range | -2.00 to 14.00 pH |
| pH: Resolution | 0.01 pH |
| pH: Accuracy | ± 0.01 pH |
| pH: Calibration Points | Up to 2 |

MET21-20
pH Meter
| pH: Range | -2.00 to 20.00 pH |
| pH: Resolution | 0.1, 0.01 pH |
| pH: Accuracy | ± 0.01 pH |
| pH: Calibration Points | Up to 5 |

MET31-003
Conductivity Meter
| Conductivity: Range | 0.000 μS/cm to 1000 mS/cm |
| Conductivity: Resolution | 0.001 μS/cm minimum; changed with range |
| Conductivity: Accuracy | ± 1.0 % FS |
| Conductivity: Reference Temperature | 20, 25 °C |

MET31-003A
Conductivity Meter
| Conductivity: Range | 0.000 μS/cm to 500 mS/cm |
| Conductivity: Resolution | 0.001 μS/cm minimum; changed with range |
| Conductivity: Accuracy | ± 1.0 % FS |
| Conductivity: Reference Temperature | 20, 25 °C |

MET31-005
Conductivity Meter
| Conductivity: Range | 0.000 μS/cm to 3000 mS/cm |
| Conductivity: Resolution | 0.001 μS/cm minimum; changed with range |
| Conductivity: Accuracy | ± 0.5 % FS |
| Conductivity: Reference Temperature | 5, 10, 15, 18, 20, 25 °C |

MET31-005A
Conductivity Meter
| Conductivity: Range | 0.000 μS/cm to 3000 mS/cm |
| Conductivity: Resolution | 1.001 μS/cm minimum; changed with range |
| Conductivity: Accuracy | ± 0.5 % FS |
| Conductivity: Reference Temperature | 5, 10, 15, 18, 20, 25 °C |

MET31-025
Conductivity Meter
| Conductivity: Range | 0.00 μS/cm to 100 mS/cm |
| Conductivity: Resolution | 0.01 μS/cm minimum; changed with range |
| Conductivity: Accuracy | ± 1.0 % FS |
| Conductivity: Reference Temperature | 25 °C |

MET31-100
Conductivity Meter
| Conductivity: Range | 0.00 μS/cm to 100 mS/cm |
| Conductivity: Resolution | 0.01 μS/cm minimum; changed with range |
| Conductivity: Accuracy | ± 1.5 % FS |
| Conductivity: Reference Temperature | 25 °C |

MET31-200
Conductivity Meter
| Conductivity: Range | 0.00 μS/cm to 200 mS/cm |
| Conductivity: Resolution | 1.01 μS/cm minimum; changed with range |
| Conductivity: Accuracy | ± 1.0 % FS |
| Conductivity: Reference Temperature | 25 °C |

MET41-010
DO Meter
| Dissolved Oxygen Concentration: Sensor Type | Polarographic |
| Dissolved Oxygen Concentration: Range | 1.00 to 99.99 mg/L |
| Dissolved Oxygen Concentration: Resolution | 1.01 mg/L |
| Dissolved Oxygen Concentration: Accuracy | ± 0.3 mg/L (0.00 to 20.00 mg/L) ± 10% (20.00 to 99.99 mg/L) |

MET41-020
DO Meter
| Dissolved Oxygen Concentration: Sensor Type | Polarographic |
| Dissolved Oxygen Concentration: Range | 0.00 to 99.99mg/L |
| Dissolved Oxygen Concentration: Resolution | 0.01 mg/L |
| Dissolved Oxygen Concentration: Accuracy | ± 0.3 mg/L (0.00 to 20.00 mg/L) ± 10% (20.00 to 99.99 mg/L) |

MET41-230
DO Meter
| Dissolved Oxygen Concentration: Sensor Type | Polarographic |
| Dissolved Oxygen Concentration: Range | 0.00 to 20.00 mg/L |
| Dissolved Oxygen Concentration: Resolution | 1.01 mg/L |
| Dissolved Oxygen Concentration: Accuracy | ± 0.3 mg/L |

MET41-600
DO Meter
| Dissolved Oxygen Concentration: Sensor Type | Polarographic |
| Dissolved Oxygen Concentration: Range | 0.00 to 99.99 mg/L |
| Dissolved Oxygen Concentration: Resolution | 2.01 mg/L |
| Dissolved Oxygen Concentration: Accuracy | ± 0.1 mg/L |

MET51-010
pH/Ion Meter
| Dissolved Oxygen Concentration: Sensor Type | Optical |
| Dissolved Oxygen Concentration: Range | 0.00 to 20.00 mg/L |
| Dissolved Oxygen Concentration: Resolution | 1.01mg/L |
| Dissolved Oxygen Concentration: Accuracy | ±0.3 mg/L(0.00 to 20.00 mg/L) |

MET51-020
pH/Ion Meter
| pH: Range | -2.00 to 20.00 pH |
| pH: Resolution | 0.1, 0.01 pH |
| pH: Accuracy | ± 0.01 pH |
| pH: Calibration Points | Up to 5 |

MET51-135
pH/Ion Meter
| pH: Range | -2.000 to 20.000 pH |
| pH: Resolution | 0.1, 0.01, 0.001 pH |
| pH: Accuracy | ± 0.002 pH |
| pH: Calibration Points | Up to 8 |

MET51-230
pH/Ion Meter
| pH: Range | -2.000 to 20.000 pH |
| pH: Resolution | 0.1, 0.01, 0.001 pH |
| pH: Accuracy | ± 0.002 pH |
| pH: Calibration Points | Up to 6 |

MET51-275
pH/Ion Meter
| Dissolved Oxygen Concentration: Sensor Type | Polarographic |
| Dissolved Oxygen Concentration: Range | 0.00 to 99.99 mg/L |
| Dissolved Oxygen Concentration: Resolution | 2.01 mg/L |
| Dissolved Oxygen Concentration: Accuracy | ± 0.3 mg/L (0.00 to 20.00 mg/L) ± 10 % (20.00 to 99.99 mg/L) |

MET51-300
pH/Ion Meter
| pH: Range | -2.00 to 20.00 pH |
| pH: Resolution | 0.1, 0.01 pH |
| pH: Accuracy | ± 0.01 pH |
| pH: Calibration Points | Up to 5 |

MET51-600
pH/Ion Meter
| pH: Range | -3.000 to 20.000 pH |
| pH: Resolution | 1.1, 0.01, 0.001 pH |
| pH: Accuracy | ± 0.002 pH |
| pH: Calibration Points | Up to 7 |

MET61-008
Multi-parameter Analyzer
| pH: Range | -2.000 to 20.000 pH |
| pH: Resolution | 0.1, 0.01, 0.001 pH |
| pH: Accuracy | ± 0.002 pH |
| pH: Calibration Points | Up to 8 |

MET61-110
Multi-parameter Analyzer
| pH: Range | -2.00 to 20.00 pH |
| pH: Resolution | 0.1, 0.01 pH |
| pH: Accuracy | ± 0.02 pH |
| pH: Calibration Points | Up to 5 |

MET61-135
Multi-parameter Analyzer
| pH: Range | -2.000 to 20.000 pH |
| pH: Resolution | 0.1, 0.01, 0.001 pH |
| pH: Accuracy | ± 0.002 pH |
| pH: Calibration Points | Up to 8 |

MET61-200
Multi-parameter Analyzer
| pH: Range | -3.00 to 20.00 pH |
| pH: Resolution | 1.1, 0.01 pH |
| pH: Accuracy | ± 0.01 pH |
| pH: Calibration Points | Up to 6 |

MET61-230
Multi-parameter Analyzer
| pH: Range | -2.00 to 20.00 pH |
| pH: Resolution | 0.1, 0.01 pH |
| pH: Accuracy | ± 0.01 pH |
| pH: Calibration Points | Up to 5 |

MET61-275
Multi-parameter Analyzer
| pH: Range | -2.000 to 20.000 pH |
| pH: Resolution | 0.1, 0.01, 0.001 pH |
| pH: Accuracy | ± 0.002 pH |
| pH: Calibration Points | Up to 7 |

MET61-300
Multi-parameter Analyzer
| pH: Range | -2.00 to 20.00 pH |
| pH: Resolution | 0.1, 0.01 pH |
| pH: Accuracy | ± 0.02 pH |
| pH: Calibration Points | Up to 5 |

MET61-500
Multi-parameter Analyzer
| pH: Range | -2.00 to 20.00 pH |
| pH: Resolution | 0.1, 0.01 pH |
| pH: Accuracy | ± 0.02 pH |
| pH: Calibration Points | Up to 5 |

MET61-600
Multi-parameter Analyzer
| pH: Range | -3.000 to 20.000 pH |
| pH: Resolution | 1.1, 0.01, 0.001 pH |
| pH: Accuracy | ± 0.002 pH |
| pH: Calibration Points | Up to 7 |

MET71-200
Turbidity Meter
| Measuring Unit: Range | (0 ~20.00) NTU, (20.0 ~200.0) NTU |
| Measuring Unit: Resolution | 0.01NTU, 0.1NTU, 1NTU |
| Measuring Unit: Accuracy | ≤ ±8 % |
| Measuring Unit: Fluctuation | ≤ 1.0 % |

MET71-232
Turbidity Meter
| Measuring Unit: Range | (0.000 ~20.00) NTU, (20.01 ~200.0) NTU, (200 ~2000) NTU, (2001 ~4000) NTU |
| Measuring Unit: Accuracy | ≤ ±6% |
| Measuring Unit: Repeatability | ≤ 0.5 % |
| Measuring Unit: Fluctuation | ≤ ±0.5 % FS/30xmin |

MET71-240
Turbidity Meter
| Measuring Unit: Range | (0 ~20.00) NTU, (20.0 ~200.0) NTU |
| Measuring Unit: Accuracy | ≤ ±8% |
| Measuring Unit: Repeatability | ≤ 1.0 % |
| Measuring Unit: Fluctuation | ≤ ±1.0 % FS/30xmin |

MET81-040
Colorimeter
| Optical Geometry | 8°/D |
| Standards compliant | CIE No.l5, GB/T 3981 |
| Sensor | Silicon Photoelectric Diode Array |
| Measuring Aperture | Φ 4 mm |

MET81-045
Colorimeter
| Optical Geometry | 45°/0° |
| Standards compliant | CIE No.15,GB/T 3978. |
| Sensor | Silicon Photoelectric Diode Array |
| Measuring Aperture | Φ8mm flat |

MET81-065
Colorimeter
| Optical Geometry | 8°/D |
| Standards compliant | CIE No.l5, GB/T 3980 |
| Sensor | Silicon Photoelectric Diode Array |
| Measuring Aperture | Φ 4 mm flat, Φ 4 mm sharp |

MET81-100
Colorimeter
| Optical Geometry | 8°/D |
| Standards compliant | CIE No.15,GB/T 3978. |
| Sensor | Silicon Photoelectric Diode Array |
| Measuring Aperture | Φ8mm flat and Φ4mm tip |

MET81-400
Colorimeter
| Optical Geometry | 45°/0° |
| Standards compliant | CIE No.l5, GB/T 3979 |
| Sensor | Silicon Photoelectric Diode Array |
| Measuring Aperture | Φ 20 mm |

MET81-500
Colorimeter
| Optical Geometry | 8°/D |
| Standards compliant | CIE No.l5, GB/T 3978 |
| Sensor | Silicon Photoelectric Diode Array |
| Measuring Aperture | Φ 8 mm flat, Φ 4 mm sharp |

MET91-040
Gloss Meter
| Measuring Angle | 60° |
| Measuring Area (mm) | 60°:9X15 |
| Measuring Range | 60°:0~200 GU |
| Division Value | 1 GU |

MET91-060
Gloss Meter
| Optical Geometry | 60° |
| Standards compliant | ISO 2813, ASTM D 523,GB/T 9754, |
| Facula (mm) | 9x15 |
| Measuring range | 0-1000 GU |

MET91-060A
Gloss Meter
| Measuring Angle | 60° |
| Measuring Area (mm) | 60°:9X15 |
| Measuring Range | 60°:0~1000 GU |
| Division Value | 0.1 GU |

MET91-085
Gloss Meter
| Optical Geometry | 20°/60°/85° |
| Standards compliant | ISO 2813, ASTM D 523,GB/T 9754 |
| Facula (mm) | 20°:10x10 60°:9x15 85°:5x36 |
| Measuring range | 20°:0~2000 GU 6Q°:0~1000 GU 85°: 0-160 GU |

MET91-160
Gloss Meter
| Measuring Angle | 20°/60°/85° |
| Measuring Area (mm) | 20°:9x10 60°:9x15 85°:5x38 |
| Measuring Range | 20°: 0-2000 GU 60°: 0-1000 GU 85°: 0-160 GU |
| Division Value | 0.1 GU |

MET91-200
Gloss Meter
| Optical Geometry | 60° |
| Standards compliant | ISO 2813, GB/T9754, ASTM D 523 |
| Characteristic | It can be used for gloss measurement in paint, ink, paint, paper printing, plastic electronics, furniture, ceramics, electroplating, hardware, marble and other industries. Provide basic measurement mode, Meet the basic gloss test. Large color display that displays multiple sets of test data simultaneously. |
| Facula(mm) | 9x15 |

MET91-300
Gloss Meter
| Optical Geometry | 60° |
| Standards compliant | ISO 2813, GB/T9754, ASTM D 523 |
| Characteristic | It can be used for gloss measurement in paint, ink, paint, paper printing, plastic electronics, furniture, ceramics, electroplating, hardware, marble and other industries. Provide basic measurement mode, Meet the basic gloss test. Large color display that displays multiple sets of test data simultaneously. |
| Facula(mm) | 9x15 |