Microwave Digester
A well-known method for preparing solid materials into solutions fit for examination by ICP-AES, ICP-MS, atomic absorption spectroscopy, or polarography is microwave digestion.
Download Catalog
Note: To download a single product catalog please goto the product page and download catalog

MWD11-06
Microwave Digester
| Vessel Quantity | 6 |
| Temperature Monitoring System | Contactless IR sensor All vessels scanning monitoring |
| Pressure Monitoring System | Contactless pressure sensors. All vessels scanning monitoring |
| Working Pressure Range | 0-6MPa |

MWD12-08
Microwave Digester
| Vessel Quantity | 8 |
| Pressure Monitoring System | Contactless pressure sensors. All vessels scanning monitoring |
| Working Pressure Range | 0-6MPa |
| Working Temperature Range | 50-400 °C Accuracy: ±0.1°C |

MWD13-10
Microwave Digester
| Vessel Quantity | 10 |
| Pressure Monitoring System | Contactless pressure sensors. All vessels scanning monitoring |
| Working Pressure Range | 0-6MPa |
| Working Temperature Range | 50-400 °C Accuracy: ±0.1 °C |

MWD14-06
Microwave Digester
| Vessel Quantity | 6 |
| Temperature Monitoring System | Temperature Monitoring: Contactless IR Sensor Scan monitoring for each vessel Temperature Controlling Range: 50-400 ?C Temperature Accuracy: ?0.1 ?C Display Accuracy: ?0.1 ?C |
| Pressure Monitoring System | Pressure monitoring: Contactless Sensor Scan monitoring for each vessel Pressure Controlling Range: 0-15MPa Pressure Accuracy:?0.01MPa Display Accuracy: ?0.01Mpa |
| Vessel Volume | 100mL |

MWD15-08
Microwave Digester
| Vessel Quantity | 8 |
| Temperature Monitoring System | Temperature Monitoring: Contactless IR Sensor Scan monitoring for each vessel Temperature Controlling Range: 50-400 ?C Temperature Accuracy: ?0.1 ?C Display Accuracy: ?0.1 ?C |
| Pressure Monitoring System | Pressure monitoring: Contactless Sensor Scan monitoring for each vessel Pressure Controlling Range: 0-15MPa Pressure Accuracy:?0.01MPa Display Accuracy: ?0.01Mpa |
| Vessel Volume | 100mL |

MWD16-10
Microwave Digester
| Vessel Quantity | 10 |
| Temperature Monitoring System | Temperature Monitoring: Contactless IR Sensor Scan monitoring for each vessel Temperature Controlling Range: 50-400 ?C Temperature Accuracy: ?0.1 ?C Display Accuracy: ?0.1 ?C |
| Pressure Monitoring System | Pressure monitoring: Contactless Sensor Scan monitoring for each vessel Pressure Controlling Range: 0-15MPa Pressure Accuracy:?0.01MPa Display Accuracy: ?0.01Mpa |
| Vessel Volume | 100mL |

MWD17-12
Microwave Digester
| Vessel Quantity | 12 |
| Temperature Monitoring System | Temperature Monitoring: Contactless IR Sensor Scan monitoring for each vessel Temperature Controlling Range: 50-400 ?C Temperature Accuracy: ?0.1 ?C Display Accuracy: ?0.1 ?C |
| Pressure Monitoring System | Pressure monitoring: Contactless Sensor Scan monitoring for each vessel Pressure Controlling Range: 0-15MPa Pressure Accuracy:?0.01MPa Display Accuracy: ?0.01Mpa |
| Vessel Volume | 100mL |

MWD18-12
Microwave Digester
| Vessel Quantity | 12 |
| Vessel Volume | 100mL |
| Vessel material | Inner.Imported TFM Outer.Imported PEEK+Glass Fiber |
| Temperature Monitoring System | Contactless IR sensor |

MWD19-18
Microwave Digester
| Vessel Quantity | 18 |
| Vessel Volume | 100mL |
| Vessel material | Inner.Imported TFM Outer.Imported PEEK+Glass Fiber |
| Temperature Monitoring System | Contactless IR sensor |

MWD20-40
Microwave Digester
| Vessel Quantity | 40 |
| Vessel Volume | 50mL |
| Vessel material | Inner.Imported TFM Outer.Imported PEEK Glass Fiber |
| Temperature Monitoring System | Contactless IR sensor |

MWD21-12
Microwave Digester
| Vessel Quantity | 12 |
| Vessel Volume | 100mL |
| Vessel Pressure Capacity | 80Mpa |
| Cavity | 48L Resonant Cavity |

MWD22-12
Microwave Digester
| Vessel Quantity | 12 |
| Vessel Volume | 100mL |
| Vessel Pressure Capacity | 75Mpa |
| Cavity | 48L Resonant Cavity |

MWD23-06
Microwave Digester
| Vessel Quantity | 6 |
| Vessel Volume | 100mL |
| Vessel material | Aerospace composite fiber for outer Vessel, Modified TFM material for inner Vessel |
| Temperature Range | 0-300 °C |

MWD24-30
Microwave Digester
| Temperature Range | RT +5 ± 450 °C |
| Temperature Accuracy | ±1 °C (450 °C) |
| Heating Method | Infrared heating and high-purity graphite conduction |
| Heating Insulation Method | Unique air duct insulation technology |