Viscometer Petroleum Equipment
Viscosity of an oil is defined as its resistance to flow and Viscometer measures the flow. Monitoring viscosity is one of the most important components of any oil analysis program. Minute changes in viscosity at operating temperatures can be magnified to the extent that an oil is no longer able to provide adequate lubrication and efficiency in preventing friction between moving parts.
Used in Materials Science, Chemical Industries, Oil and Gas Industry, Petroleum Industry.
Also known as Viscometer, Viscosity meter, Rheometer.
Download Catalog
Note: To download a single product catalog please goto the product page and download catalog

PTL11-04
Kinematic Viscometer
| Working unit | 4 tubes |
| Temperature controlling method | Imported PID digital temperature controller |
| Temperature controlling accuracy | ± 0.1 ℃ |
| Heating method | Electrical heating tube |

PTL12-02
Low Temperature Kinematic Viscometer
| Working units | 2 |
| Temperature controlling range | 50 – 40 °C ± 0. 1 °C |
| Refrigerated by | Shock absorption air compressor,Fluorine free |
| Safety | Device can prevent over-low liquid level |

PTL13-05
Mini Rotary Viscometer
| Temperature range | - 5 °C – 40 °C ± 0.02 °C |
| Temperature control | Automatic nonlinear curve |
| Window operation system | XP, Win7 |
| Optional accessory | Test components of ASTM D6896 and ASTM D6821 |

PTL14-05
High Temperature High Shear Viscometer
| Test units | 5 |
| Test samples | 10 - 20 every hour |
| Calibration error of standard oil | Automatically calculated |
| Working Conditions | 24 hours continuous working for 365 days |

PTL15-01-A
Low Temperature Brookfield Viscometer
| Lifting method | One-click, Automatic |
| Operation method | Touch screen |
| Cooling | Peltier cooling can test after 2 hours constant temperature |

PTL16-01-E
Engler Viscometer
| Temperature controlling method | Imported PID digital temperature controller |
| Temperature controlling accuracy | ± 0.1 ℃ |
| Heating method | Electrical heating tube |
| Total power | 3.5 KW |

PTL17-06
Low Temperature Kinematic Viscometer
| Capillary viscometer tubes (Pinkevitch viscometer) | 6 pieces in total and the diameters for each is 0.6, 0.8, 1.0, 1.2, 1.5, 2.0 mm. |
| Temperature range | - 65 ℃~room temp |
| Temperature control accuracy | ± 0.1 ℃ |
| Ambient temperature | 15 ℃~35 ℃ |

PTL18-80
Automatic Capillary Viscometer Washer
| Water bath temperature control range | Ambient to 80 ℃ |
| Ambient temperature | 15 ℃ ~ 35 ℃ |
| Relative humidity | ≤ 85 % |
| Maximum power consumption | 700 W |