Chromatography
Chromatography is a technique that enables the separation, identification, and purification of the components of a mixture for qualitative and quantitative analysis. Our extensive range offers variety of products like Gas, Ion and Portable Ion chromatography products to meet all separation needs, including improved resolution, enhanced sensitivity, faster analysis and consistent performance.
Sub Categories
Download Catalog
Note: To download a single product catalog please goto the product page and download catalog

CHR11-400G
Gas Chromatography
| Column Oven: Inner volume | 22 L |
| Column Oven: Temperature Range | 5°C – 400°C (room temperature) |
| Column Oven: Temperature Control Accuracy | ± 0.1°C |
| Column Oven: Heating Rate | 0.1 - 60°C /min |

CHR12-399G
Gas Chromatography
| Column Oven: Temperature Range | 15°C – 399°C above room temperature (increment: 1°C) |
| Column Oven: Temperature Control Accuracy | Better than ± 0.1°C (measured at 200°C) |
| Hydrogen flame ionization detector (FID): Detection limit | Dt ≤ 1x10-10 g/s (octane and hexadecane) |
| Hydrogen flame ionization detector (FID): Baseline drift | ≤ 2x10– 12 A/h |

CHR13-400G
Gas Chromatography
| Column Oven: Temperature Range | Ambient temperature +7°C ~ 400°C (in 1°C increment) |
| Column Oven: Temperature Control Accuracy | ± 0.02°C |
| Column Oven: Programmed temperature setting | 0.1°C ~ 40°C/min (in 1°C increment) |
| Column Oven: Program ramps | 7 ramps in total (10 ramps available with control workstation) |

CHR14-450G
Gas Chromatography-Mass Spectrometry
| GC Specification: Inlet | Split / Splitless |
| GC Specification: Inlet Temperature | Highest temperature 450°C |
| GC Specification: Electronic Pressure Control(EPC)Range | 0-50 Psi, accuracy 0.1 Psi, support constant |
| GC Specification: Maximum Diffluent Ratio | 500:1 |

CHR15-042I
Ion Chromatography
| Ion Chromatographic Pump: Maximum Pressure | 42 Mpa (Stainless steel) |
| Ion Chromatographic Pump: Type | High-pressure and low-pulse two-piston tandem advection pump |
| Ion Chromatographic Pump: Pressure Display Accuracy | ≤ 0.1 MPa |
| Ion Chromatographic Pump: Flow Range | 0.001 ~ 9.999 mL/min |

CHR16-035I
Ion Chromatography
| Ion Chromatographic Pump: Maximum Pressure | 35 Mpa (PEEK) |
| Ion Chromatographic Pump: Type | High-pressure and low-pulse two-piston tandem advection pump |
| Ion Chromatographic Pump: Pressure Display Accuracy | ≤ 0.1 MPa |
| Ion Chromatographic Pump: Flow Range | 0.001 ~ 9.999 mL/min |

CHR17-035I
Ion Chromatography
| Ion Chromatographic Pump: Maximum Pressure | 35 Mpa (PEEK) |
| Ion Chromatographic Pump: Type | High-pressure and low-pulse two-piston tandem advection pump |
| Ion Chromatographic Pump: Pressure Display Accuracy | ≤ 0.1 MPa |
| Ion Chromatographic Pump: Flow Range | 0.001 ~ 9.999 mL/min |

CHR18-035I
Ion Chromatography
| Ion Chromatographic Pump: Maximum Pressure | 35 Mpa (PEEK) |
| Ion Chromatographic Pump: Type | High-pressure and low-pulse two-piston tandem advection pump |
| Ion Chromatographic Pump: Pressure Display Accuracy | ≤ 0.1 MPa |
| Ion Chromatographic Pump: Flow Range | 0.001 ~ 9.999 mL/min |