Rotary Evaporator REV12-180D
Rotary Evaporator is an essential instrument in laboratory for the efficient and gentle removal of solvents from samples by evaporation. Besides, it provides excellent distilling solution in a wide range of applications. It can be used as a multi-functional system in combination with vacuum pump, vacuum controller and circulating refrigerators which makes it an unique choice for the laboratory.
Used in Evaporation, Distillation, Separation of chemicals, Drying, Extraction, Recovery, Chemical Laboratory, Biological Laboratory, Pharmaceutical
Also known as Rotovap, Rotavapor, Laboratory Rotary Evaporator, Laboratory Rotovap
- Water/oil heating mode can be changed only through a switch.
- Safety: Motor over-current protection, Residual Current Device, lifting overload protection, Boil-dry protection, over-temperature protection.
- Timing interval operation in clockwise and anticlockwise directions for drying process.
- Excellent cooling effect.
Features
- Water/oil heating mode can be changed only through a switch.
- Safety: Motor over-current protection, Residual Current Device, lifting overload protection, Boil-dry protection, over-temperature protection.
- Timing interval operation in clockwise and anticlockwise directions for drying process.
- Excellent cooling effect.
- Patented double spring sealing ring which is made of PTFE provides an excellent sealing performance.
Specifications
Evaporation Capacity | Max.4.0 L/h (water vapor volume) |
Motor Lift | Automatic |
Ultimate Vacuum | Less 2.6 hpa |
Rotation Speed | 10-150 rpm |
Display | LCD (temperature/speed/clockwise and Anti-clockwise/time) |
Temperature control method | Micro processer PID control |
Heating Temperature Range | Room temp. to 180°C (both water and oil) |
Control Accuracy | water: ±1°C oil: ±3°C |
Stroke Displacement | Automatic 180 mm |
Sample Flask | Round flask 20L |
Receiving Flask | Round flask 10 L with drain valve |
Adjustable Immersion Angle | No |
Condenser | Two-section vertical triple serpentine condenser, cooling surface 1.2 m² |
Takeover Caliber | Cooling/suction nozzle outer diameter 16 mm, vacuum pump nozzle outer diameter 16 mm |
Heating Bath Size | ɸ450×240 mm |
Dimension[L×W×H] | 1160x600x1860 mm |
Voltage / Frequency | 220 V/ 50/60 Hz |
Power | 4600 W |
Notes | Three-layer high-efficiency condensing tube with large condensation area and strong evaporation capacity, ensuring efficient sample recovery. A switching valve for continuous collection without compromising the system vacuum and solvent distillation. |