Home / Oven / Incubator / CO2 Incubator Air Jacketed / CO2 Incubator Air Jacketed INC072-190

CO2 Incubator Air Jacketed INC072-190

  • LCD screen, micro computer PID control that can display temp. CO2 concentration, related humidity, operation failure reminder and menu operation are easily to observe and use
  • 90 degree high temp. high humidity sterilization system (RHP) can thoroughly sterilize the chamber (Including temp. sensor, CO2 concentration sensor, fan, shelves and brackets etc) with high temp and high humidity
  • It eliminates bacteria, mold, mycoplasma etc microbiology those will pollute the microorganisms cell culture and provides a safe experiment environment
  • Cycle fan speed can be adjusted automatically.

Features

  • LCD screen, micro computer PID control that can display temp. CO2 concentration, related humidity, operation failure reminder and menu operation are easily to observe and use
  • 90 degree high temp. high humidity sterilization system (RHP) can thoroughly sterilize the chamber (Including temp. sensor, CO2 concentration sensor, fan, shelves and brackets etc) with high temp and high humidity
  • It eliminates bacteria, mold, mycoplasma etc microbiology those will pollute the microorganisms cell culture and provides a safe experiment environment
  • Cycle fan speed can be adjusted automatically.
  • When chamber temp. is stable, the fan speed will be lower down, the speed will be adjusted to a suitable speed that the cell can growth. It avoids the fast fan speed that evaporating the samples
  • CO2 inlet control system has pressure protection function, it prevents over pressure or low pressure to the pipes
  • High and low temp. and over temp. alarm
  • Chamber sensor failure alarm
  • Door temp. sensor failure alarm
  • Over temp sensor failure alarm
  • CO2 condensation too high or too low alarm
  • Independent temp. limiter alarm
  • Door open too long alarm
  • Disinfection and sterilization status reminder
  • All data can be stored through RS485 port, if any failures, user can read the diagnostic message and data from computer at any time.

Specifications

Capacity190 L
Electrical requirementAC 220 V / 50 Hz
Input Power750 W
Heating powerAir jacket micro computer PID control
Temp. control rangeRT+5 - 55°C
Work environment temp+5 - 30°C
Temp. accuracy±0.1°C
CO2 control range0 - 20 %
CO2 control accuracy±0.1% (IR sensor)
CO2 restore time(Door open 30s, recovery to 5%) ≤ 3min
Temp. restore time(Door open 30s, recovery to 37°C) ≤ 8min
Related humidityNature vaporate > 95%(Can equip with related humidity digital display)
Chamber size520Wx530Dx390H mm
Overall size708Wx710Dx1030H mm
Standard shelves quantity3 pcs
SterilizationUV sterilization+HEPA sterilization

Product Inquiry

Name*
Email*
I am *: Distributor End User Others
WhatsApp
Product
Subject
Message*