Home / Spectrophotometer / Atomic Absorption Spectrophotometer / Atomic Absorption Spectrophotometer SPE41-0220

Atomic Absorption Spectrophotometer SPE41-0220

Used in Food and Beverage Industry, Water Analysis, Clinical Research, Pharmaceutical, Mining and Geology, Environmental Monitoring, Oil and Petroleum, Forensics

  • Eight lamp flame/graphite furnace integrated machine. Automatic PC control three light brick, automatic alignment, automatic optimization and automatic ignition. With automatic safety protection function, anti tempering automatic gas path protection, acetylene gas leak- age alarm, automatic shutdown system, abnormal automatic power-off.

Features

  • Eight lamp flame/graphite furnace integrated machine. Automatic PC control three light brick, automatic alignment, automatic optimization and automatic ignition. With automatic safety protection function, anti tempering automatic gas path protection, acetylene gas leak- age alarm, automatic shutdown system, abnormal automatic power-off.

Specifications

Grating1800 I /mm
Wavelength Range190-900 nm
Spectral bandwidth0.1. 0.2. 0.4,. 1.0. 2.0 nm (automatic adjustable)
Wavelength accuracy≤ 0.15 nm
Wavelength repeatability: 
      ± 0.1 nm
Baseline stability≤ ± 0.002 A /30 minutes (static) ≤ ± 0.005 A /30 minutes (dynamic)
Light source≤ 8 lamps automatic turret, automatic alignment
PowerDouble cathode power built-in high performance lamps
Flame atomizer: 
      Characteristic concentration (Cu):0.015 µg/mL/1%.
      Detection limits (Cu):0.002 µg/mL
      Precision:RSD ≤ 0.5 %
      Combustion head:Metal Titanium combustion head
      Atomizer:Efficient glass atomizer
      Atomizing chamber:explosion proof corrosion resistant material spray chamber
      Control system:Automatic PC control three light brick, automatic alignment, automatic optimization and automatic ignition
      Safety protection:With automatic safety protection function, anti temperingautomatic gas path protection, acetylene gas leak- age alarm, automatic shutdown system, abnormal automatic power-off
      Background correction:Deuterium background correction: correction of the 1A background
Data processing: 
      Measurement methods:Flame method, Hydride method
      Concentration calculation method:standard curve method (1 - 3 times curve),automatic matching, the standard addition method
      Repetition survey frequency:1-99 times, calculating the average value, standard deviation and relative standard deviations are given
      Results print:parameters print, data and graphics print, you can also export WORD, EXCEL document
      Simple and convenient operation, lamp position rotating, automatic ignition through software operating
      Communication interface:Computer and USB interface communication
Power requirements: 
      220 V (+5 % ~ -10 %), 50/60 Hz; 5000 VA
Environment temperature: 
      +15 °C ~ +35 °C
Relative humidity: 
      20 ~ 80 %

Product Inquiry

Name*
Email*
WhatsApp
Product
Subject
Message*