+14135535210
contact@labstac.com
Distributor Registration
Analytical & Lab Equipment
WhatsApp
Chat Now
Get Pricelist
Home
Products
Catalogs
Manuals
News *
About
Contact
Live Chat
Air Protection
Air Protection
Dispensing Booth
Clean Booth
Pathology Workstation
PP Reagent Cabinet
Air Sterilizer
Ozone UV Sterilization Cabinet
UV Sterilization Cabinet
Analyzer
Analyzer
Hematology Analyzer
Moisture Analyzer
Differential Thermal Analyzer
IR Carbon Sulfur Analyzer
TOC Analyzer
Electrolyte Analyzer
Milk Analyzer
Auto Chemistry Analyzer
Auto Coagulation Analyzer
Fluorescence Immunoassay Analyzer
Thermogravimetric analysis
ESR Analyzer
Autoclave
Autoclave
Vertical Autoclave
Horizontal Autoclave
Medical Autoclave
Portable Autoclave
Automated Solid Phase Extraction System
Automated Solid Phase Extraction System
Manual Solid Phase Extraction System
Automated Solid Phase Extraction System
Balance
Balance
Analytical Balance
Precision Balance
Density Balance
Weighing Scale
Bath and Circulator
Bath and Circulator
Oil Bath Circulator
Dry Bath Incubator
Dual Temperature Dry Bath Incubator
Mini Dry Bath Incubator
Water Bath
Dry Bath
Dry Bath Chiller
Low Temperature Circulator
Cold Trap Bath
Shaking Water Bath
High Temperature Circulator
Biological Safety Cabinet
Biological Safety Cabinet
Class I Biological Safety Cabinet
Class II Biological Safety Cabinet
Class III Biological Safety Cabinet
Medical Biological Safety Cabinet
Air Shower pass box
Pass Box
Air Shower
Blood Culture System
Blood Culture System
Automated Blood Culture System
Cabinet
Cabinet
Weak acid and alkali Chemical storage cabinet
Strong acid and Alkali Storage Cabinet
Centrifuge
Centrifuge
Tabletop Centrifuge
Floor Type Centrifuge
Medical Centrifuge
Microcentrifuge
Chamber
Chamber
Climatic Chamber
Plant Growth Chamber
Stability Test Chamber
Xenon Test Chamber
UV Test Chamber
Chiller
Chiller
Air Cooled Chiller
Water Chiller
Chromatography
Chromatography
Chromatography
Clinical Microbial Diagnosis
Clinical Microbial Diagnosis
Identification And Antibiotic Susceptibility Testing
Colony Counter
Colony Counter
Bacterial Colony Counter
Colonometer
Cell Counters
Concentrator
Concentrator
Concentrator
Differential Scanning Calorimeter
Differential Scanning Calorimeter
Differential Scanning Calorimeter
Dosimeter
Dosimeter
Dosimeter
Drug Detector
Drug Detector
Explosive Drug Detector
Trace Drug Detector
Hand-Held Chemical Identifier
Freeze Dryer
Freeze Dryer
Bench Top Freeze Dryer
Floor Type Freeze Dryer
Fume Hood
Fume Hood
Standard Fume Hood
Ductless Fume Hood
Ducted fume hood
Mobile fume extractor
Walk in fume hood
FFU (fan filter unit )
Gas Generator
Gas Generator
Hydrogen Generator
Air Generator
Nitrogen Generator
Hydrogen Air Generator
Nitrogen Air Generator
Hydrogen Nitrogen Air Generator
Gel Instrument
Gel Instrument
Gel Instrument
Glassware Washer
Glassware Washer
Lab Automatic Glassware Washer
Medical Automatic Glassware Washer
Histopathology Equipment
Histopathology Equipment
Cryostat
Microtome
Tissue Processor
Staining System
Printing System
Tissue Embedding System
Fast Freezing Machine
Hospital bed
Hospital bed
Electric Hospital Bed
Manual Hospital Bed
Delivery table
Children medical Bed
Orthopedic Traction Bed
Stainless Steel Bed
Dialysis Bed
Strecher
Wheelchair
Ice Maker
Ice Maker
Bullet Ice Maker
Cube Ice Maker
Ice Flaker
Kjeldahl Systems
Kjeldahl Systems
Graphite Digester
Kjeldahl Analyzer
Laminar Air Flow
Laminar Air Flow
Desktop Laminar Airflow
Horizontal Laminar Airflow
Vertical Laminar Airflow
Compounding Hood
Liquid Handling
Liquid Handling
Automatic Sealing and Capping Machine
Sample tube scanner
Ultrasonic Homogenizer
Portable Ultrasonic Processor
Cup Type Ultrasonic Processor
Automated Sample Processing System
Homogenizer
Meters
Meters
pH Meter
pH/Ion Meter
Turbidity Meter
DO Meter
Conductivity Meter
Colorimeter
Thermal Imaging Camera Meters
Multi-parameter Analyzer
Gloss Meter
Haze Meter
Microplate Reader and Washer
Microplate Reader and Washer
Microplate Reader
Microplate Washer
Microscope
Microscope
Microcirculation Microscope
Biological Microscope
Metallurgical Microscope
Stereo Zoom Microscope
Microwave Digestion
Microwave Digestion
Microwave Digester
Mixer
Mixer
Vortex Mixer
Roller
Rotator
Vortex Mixer
Nucleic Acid Purification System
Nucleic Acid Purification System
Nucleic Acid Purification System
Automatic Nucleic Acid Extraction System
Operation Light
Operation Light
LED operation light
Digital Image operation light
Hole type operation light
Integrated operation light
Single-hole lamp
Operation Table
Operation Table
Electric Operation table
Manual Operation table
Orthopedics tractor rack
Multifunctional operation table
Oven / Incubator
Oven / Incubator
Drying Oven
Biological Indicator Incubator
BOD Incubator
Cooled Incubator
General Purpose Incubator
Platelet Incubator
CO2 Incubator Air Jacketed
CO2 Incubator Water Jacketed
Air-jacketed Multi gas Incubator
Biochemical Incubator
Gel Card Incubator
Microbiological Incubator
Microplate Incubator
Anaerobic Incubator
Vacuum Drying Oven
Hybridization Oven
Infant Incubator
Forced Convection Oven
Natural Convection Oven
Natural Convection Incubator
Paraffin Trimmer
Paraffin Trimmer
Paraffin Trimmer
PCR
PCR
Gradient PCR Thermal Cycler
Mini-PCR
Real-time Thermal Cycler
Thermal Cycler
Plate Sealer
Petroleum Equipment
Petroleum Equipment
Viscometer Petroleum Equipment
Tester Petroleum Equipment
Meters Petroleum Equipment
Machine Petroleum Equipment
Pipette
Pipette
Bottle Top Dispenser
Liquid Dispenser
Multi Channel Pipette
Pipette Controller
Single Channel Pipette
Pipette Consumables
Pipette Consumables
Pipette Bulb
Pipette Pump
Pipette Stand
Pipette Tips
Pipettor Solution Basins
Serological Pipette
Tips Box
Polarimeter
Polarimeter
Automatic Polarimeter
Refrigerator
Refrigerator
Blood Bank Refrigerator
Medical Refrigerator
Portable Refrigerator
Rotary Evaporator
Rotary Evaporator
Rotary Evaporator
Shaker
Shaker
Cooled Shaking Incubator
Orbital Shaker
Thermo Shaker Incubator
Microplate Shaker
Microplate Shaker Incubator
Rocking Shaker
Incubator Shaker
Spectrophotometer
Spectrophotometer
Double Beam UV Visible Spectrophotometer
Nano Spectrophotometer
Single Beam UV Visible Spectrophotometer
Flame Photometer
Atomic Absorption Spectrophotometer
Inductively Coupled Plasma Emission Spectrometer
Refractometer
Benchtop Spectrophotometer
Handheld Spectrophotometer
Portable Spectrocolorimeter
Multi Angle Spectrophotometer
Spectrodensitometer
Sterilizer
Sterilizer
Bacti-cinerator Sterilizer
Glass Bead Sterilizer
UVC Sterilizer
Stirrer
Stirrer
Homogenizer
Magnetic Hotplate Stirrer
Magnetic Stirrer
Multistation Magnetic Stirrer
Overhead Stirrer
Hotplate
Stomacher
Stomacher
Stomacher
Ultra Low Temperature Freezer
Ultra Low Temperature Freezer
-150°C Freezer
-25°C Freezer
-40°C Freezer
-60°C Freezer
-86°C Freezer
Biosafety Transport Box
Combined Refrigerator and Freezer
Ultrasonic Cleaner
Ultrasonic Cleaner
Digital Desktop ultrasonic cleaner
Desktop Multi frequency type Ultrasonic Cleaner
Digital Display Ultrasonic Cleaner
Mechanical Ultrasonic desktop cleaner
High frequency desktop ultrasonic Cleaner
Carburetor Ultrasonic
Single Frequency type Ultrasonic Cleaner
Double adjustable frequencies ultrasonic cleaner
Ultrasonic Cleaner
Vacuum Pump
Vacuum Pump
Liquid Suction Vacuum Pump
Mini Vacuum Pump
Water Purification System
Water Purification System
Large Capacity Water Purification System
Pure Water Supply
Deionized Water Purification System
Double stage RO ultrapure Water Purification System
RO Water Purification System
Ultrapure Water Purification System
Go to All Products...
Post Your Requirement
Home
/
Search
Conductivity of RO water quality : Search Results
Models
CEN46-140R
Refrigerated Microcentrifuge
Maximum Capacity (No of tubes x Vol.):
12x5 ml
Temp. Control Range:
-10°C to 35°C
Temperature Accuracy:
± 1°C
Maximum Speed:
14000 rpm
Add to Compare
CEN47-150R
Refrigerated Microcentrifuge
Maximum Capacity (No of tubes x Vol.):
12x5 ml
Temperature Range:
-10°C to 35°C
Temperature Accuracy:
± 1°C
Maximum Speed:
15000 rpm
Add to Compare
CEN48-150R
Refrigerated Microcentrifuge
Maximum Capacity (No of tubes x Vol.):
24x1.5/2 ml
Temperature Range:
-10°C to 40°C
Maximum Speed:
500-15000
Maximum RCF:
21400xg
Add to Compare
PTL2C-09
Water Separability Tester
Working units:
9
Stirrer:
Digital, rotating, adjustable speed
Stirring time and record separation time:
Automatically controlled
Unit of separation time:
Selective
Add to Compare
PTL2P-60
Water Washout Resistance Tester
Motor:
fixed speed 600 rpm
Temperature:
Control test temperature at 38 °C and 79 °C as per ASTM standard
Independent start:
Test shaft and Start water pump circulating system
Shaft:
Upgraded connecting shaft can quickly install and dismantle bearing and inside and outside baffle
Add to Compare
PTL2Z-15
Water content Tester
Heating control:
Can be continuously adjusted by a silicon knob, manual.
Ambient temperature:
(15-35)℃
Relative humidity:
≤ 85%
Power supply:
AC(220±10%)V,50Hz
Add to Compare
PTL2Z27-10
Crude Oil Water Content Tester
Distillation flask:
1000 ml
Receiver:
5ml,graduation is 0.05 ml
Condenser:
400mm±5mm
Heater:
heating mantle cap,500W×2,continuous adjustment
Add to Compare
WPS21-063RO
Medium Double stage RO ultrapure Water System
Feed Water Requirements*: Water Inlet:
Tap water: TDS<200 ppm (Extra pretreatment filter is recommended, if TDS>200 ppm)
Feed Water Requirements*: Temperature:
5-45°C
Feed Water Requirements*: Pressure:
1.0-4.0 Kgf/cm²
Flow Procedure**:
PF+AC+RO+RO+AC
Add to Compare
WPS21-094RO
Medium Double stage RO ultrapure Water System
Feed Water Requirements*: Water Inlet:
Tap water: TDS<200 ppm (Extra pretreatment filter is recommended, if TDS>200 ppm)
Feed Water Requirements*: Temperature:
5-45°C
Feed Water Requirements*: Pressure:
1.0-4.0 Kgf/cm²
Flow Procedure**:
PF+AC+RO+RO+AC
Add to Compare
WPS21-125RO
Medium Double stage RO ultrapure Water System
Feed Water Requirements*: Water Inlet:
Tap water: TDS<200 ppm (Extra pretreatment filter is recommended, if TDS>200 ppm)
Feed Water Requirements*: Temperature:
5-45°C
Feed Water Requirements*: Pressure:
1.0-4.0 Kgf/cm²
Flow Procedure**:
PF+AC+RO+RO+AC
Add to Compare
WPS22-020RRO
Double stage RO ultrapure Water System
Feed Water Requirements*: Water Inlet:
Tap water: TDS<200 ppm (Extra pretreatment filter is recommended, if TDS>200 ppm)
Feed Water Requirements*: Temperature:
5-45°C
Feed Water Requirements*: Pressure:
1.0-4.0 Kgf/cm²
Flow Procedure**:
PF+KDF+AC+RO+RO+AC
Add to Compare
WPS51-015
Basic RO Water System
Feed Water Requirements*: Water Inlet:
Tap water: TDS<200 ppm (Extra pretreatment filter is recommended, if TDS>200 ppm)
Feed Water Requirements*: Temperature:
5-45°C
Feed Water Requirements*: Pressure:
1.0-4.0 Kgf/cm²
Flow Procedure**:
PF+AC+RO+AC
Add to Compare
WPS51-015T
Basic RO Water System
Feed Water Requirements*: Water Inlet:
Tap water: TDS<200 ppm (Extra pretreatment filter is recommended, if TDS>200 ppm)
Feed Water Requirements*: Temperature:
5-45°C
Feed Water Requirements*: Pressure:
1.0-4.0 Kgf/cm²
Flow Procedure**:
PF+AC+RO+AC
Add to Compare
WPS51-030
Basic RO Water System
Feed Water Requirements*: Water Inlet:
Tap water: TDS<200 ppm (Extra pretreatment filter is recommended, if TDS>200 ppm)
Feed Water Requirements*: Temperature:
5-45°C
Feed Water Requirements*: Pressure:
1.0-4.0 Kgf/cm²
Flow Procedure**:
PF+AC+RO+AC
Add to Compare
WPS51-030T
Basic RO Water System
Feed Water Requirements*: Water Inlet:
Tap water: TDS<200 ppm (Extra pretreatment filter is recommended, if TDS>200 ppm)
Feed Water Requirements*: Temperature:
5-45°C
Feed Water Requirements*: Pressure:
1.0-4.0 Kgf/cm²
Flow Procedure**:
PF+AC+RO+AC
Add to Compare
WPS51-045
Basic RO Water System
Feed Water Requirements*: Water Inlet:
Tap water: TDS<200 ppm (Extra pretreatment filter is recommended, if TDS>200 ppm)
Feed Water Requirements*: Temperature:
5-45°C
Feed Water Requirements*: Pressure:
1.0-4.0 Kgf/cm²
Flow Procedure**:
PF+AC+RO+AC
Add to Compare
WPS51-045T
Basic RO Water System
Feed Water Requirements*: Water Inlet:
Tap water: TDS<200 ppm (Extra pretreatment filter is recommended, if TDS>200 ppm)
Feed Water Requirements*: Temperature:
5-45°C
Feed Water Requirements*: Pressure:
1.0-4.0 Kgf/cm²
Flow Procedure**:
PF+AC+RO+AC
Add to Compare
WPS52-015
Basic RO Water System
Feed Water Requirements*: Water Inlet:
Tap water: TDS<200 ppm (Extra pretreatment filter is recommended, if TDS>200 ppm)
Feed Water Requirements*: Temperature:
5-45°C
Feed Water Requirements*: Pressure:
1.0-4.0 Kgf/cm²
Flow Procedure**:
PF+AC+RO+AC
Add to Compare
WPS52-030
Basic RO Water System
Feed Water Requirements*: Water Inlet:
Tap water: TDS<200 ppm (Extra pretreatment filter is recommended, if TDS>200 ppm)
Feed Water Requirements*: Temperature:
5-45°C
Feed Water Requirements*: Pressure:
1.0-4.0 Kgf/cm²
Flow Procedure**:
PF+AC+RO+AC
Add to Compare
WPS21-063DI
Deionized Double stage RO ultrapure Water System
Feed Water Requirements*: Water Inlet:
Tap water: TDS<200 ppm (Extra pretreatment filter is recommended, if TDS>200 ppm)
Feed Water Requirements*: Temperature:
5-45°C
Feed Water Requirements*: Pressure:
1.0-4.0 Kgf/cm²
Flow Procedure**:
PF+AC+RO+RO+AC+DI+TF
Add to Compare
WPS21-094DI
Deionized Double stage RO ultrapure Water System
Feed Water Requirements*: Water Inlet:
Tap water: TDS<200 ppm (Extra pretreatment filter is recommended, if TDS>200 ppm)
Feed Water Requirements*: Temperature:
5-45°C
Feed Water Requirements*: Pressure:
1.0-4.0 Kgf/cm²
Flow Procedure**:
PF+AC+RO+RO+AC+DI+TF
Add to Compare
WPS21-125DI
Deionized Double stage RO ultrapure Water System
Feed Water Requirements*: Water Inlet:
Tap water: TDS<200 ppm (Extra pretreatment filter is recommended, if TDS>200 ppm)
Feed Water Requirements*: Temperature:
5-45°C
Feed Water Requirements*: Pressure:
1.0-4.0 Kgf/cm²
Flow Procedure**:
PF+AC+RO+RO+AC+DI+TF
Add to Compare
WPS22-020R
Double stage RO ultrapure Water System
Feed Water Requirements*: Water Inlet:
Tap water: TDS<200 ppm (Extra pretreatment filter is recommended, if TDS>200 ppm)
Feed Water Requirements*: Temperature:
5-45°C
Feed Water Requirements*: Pressure:
1.0-4.0 Kgf/cm²
Flow Procedure**:
PF+KDF+AC+RO+RO+DI+TF
Add to Compare
WPS22-020RQ
Deionized Double stage RO ultrapure Water System
Feed Water Requirements*: Water Inlet:
Tap water: TDS<200 ppm (Extra pretreatment filter is recommended, if TDS>200 ppm)
Feed Water Requirements*: Temperature:
5-45°C
Feed Water Requirements*: Pressure:
1.0-4.0 Kgf/cm²
Flow Procedure**:
PF+KDF+AC+RO+RO+AC+DI+TF
Add to Compare
WPS22-020RUF
Double stage RO ultrapure Water System
Feed Water Requirements*: Water Inlet:
Tap water: TDS<200 ppm (Extra pretreatment filter is recommended, if TDS>200 ppm)
Feed Water Requirements*: Temperature:
5-45°C
Feed Water Requirements*: Pressure:
1.0-4.0 Kgf/cm²
Flow Procedure**:
PF+KDF+AC+RO+RO+DI+UF+TF
Add to Compare
WPS22-020RUV
Double stage RO ultrapure Water System
Feed Water Requirements*: Water Inlet:
Tap water: TDS<200 ppm (Extra pretreatment filter is recommended, if TDS>200 ppm)
Feed Water Requirements*: Temperature:
5-45°C
Feed Water Requirements*: Pressure:
1.0-4.0 Kgf/cm²
Flow Procedure**:
PF+KDF+AC+RO+RO+UV+DI+TF
Add to Compare
WPS22-020RUVF
Double stage RO ultrapure Water System
Feed Water Requirements*: Water Inlet:
Tap water: TDS<200 ppm (Extra pretreatment filter is recommended, if TDS>200 ppm)
Feed Water Requirements*: Temperature:
5-45°C
Feed Water Requirements*: Pressure:
1.0-4.0 Kgf/cm²
Flow Procedure**:
PF+KDF+AC+RO+RO+UV+DI+UF+TF
Add to Compare
WPS53-045
Medium RO Water System
Feed Water Requirements*: Water Inlet:
Tap water: TDS<200 ppm (Extra pretreatment filter is recommended, if TDS>200 ppm)
Feed Water Requirements*: Temperature:
5-45°C
Feed Water Requirements*: Pressure:
1.0-4.0 Kgf/cm²
Flow Procedure**:
PF+AC+RO+AC
Add to Compare
WPS53-063
Medium RO Water System
Feed Water Requirements*: Water Inlet:
Tap water: TDS<200 ppm (Extra pretreatment filter is recommended, if TDS>200 ppm)
Feed Water Requirements*: Temperature:
5-45°C
Feed Water Requirements*: Pressure:
1.0-4.0 Kgf/cm²
Flow Procedure**:
PF+AC+RO+AC
Add to Compare
WPS53-094
Medium RO Water System
Feed Water Requirements*: Water Inlet:
Tap water: TDS<200 ppm (Extra pretreatment filter is recommended, if TDS>200 ppm)
Feed Water Requirements*: Temperature:
5-45°C
Feed Water Requirements*: Pressure:
1.0-4.0 Kgf/cm²
Flow Procedure**:
PF+AC+RO+AC
Add to Compare
WPS53-125
Medium RO Water System
Feed Water Requirements*: Water Inlet:
Tap water: TDS<200 ppm (Extra pretreatment filter is recommended, if TDS>200 ppm)
Feed Water Requirements*: Temperature:
5-45°C
Feed Water Requirements*: Pressure:
1.0-4.0 Kgf/cm²
Flow Procedure**:
PF+AC+RO+AC
Add to Compare
WPS54-250
Medium RO Water System
Feed Water Requirements*: Water Inlet:
Tap water: TDS<200 ppm (Extra pretreatment filter is recommended, if TDS>200 ppm)
Feed Water Requirements*: Temperature:
5-45°C
Feed Water Requirements*: Pressure:
1.0-4.0 Kgf/cm²
Flow Procedure**:
PF+AC+RO+RO+AC
Add to Compare
WPS62-045RO
Standard Medium Ultrapure Water System
Feed Water Requirements*: Water Inlet:
Tap water: TDS<200 ppm (Extra pretreatment filter is recommended, if TDS>200 ppm)
Feed Water Requirements*: Temperature:
5-45°C
Feed Water Requirements*: Pressure:
1.0-4.0 Kgf/cm²
Flow Procedure**:
PF+AC+RO+AC+DI+TF
Add to Compare
WPS62-045RO1
Standard Medium Ultrapure Water System
Feed Water Requirements*: Water Inlet:
Tap water: TDS<200 ppm (Extra pretreatment filter is recommended, if TDS>200 ppm)
Feed Water Requirements*: Temperature:
5-45°C
Feed Water Requirements*: Pressure:
1.0-4.0 Kgf/cm²
Flow Procedure**:
PF+AC+RO+AC+DI+TF
Add to Compare
WPS62-045RO2
Standard Medium Ultrapure Water System
Feed Water Requirements*: Water Inlet:
Tap water: TDS<200 ppm (Extra pretreatment filter is recommended, if TDS>200 ppm)
Feed Water Requirements*: Temperature:
5-45°C
Feed Water Requirements*: Pressure:
1.0-4.0 Kgf/cm²
Flow Procedure**:
PF+AC+RO+AC+DI+TF
Add to Compare
WPS21-063
Double stage RO ultrapure Water System
Feed Water Requirements*: Water Inlet:
Tap water: TDS<200 ppm (Extra pretreatment filter is recommended, if TDS>200 ppm)
Feed Water Requirements*: Temperature:
5-45°C
Feed Water Requirements*: Pressure:
1.0-4.0 Kgf/cm²
Flow Procedure**:
PF+AC+RO+RO+(UV)+AC+DI+(UF)+TF
Add to Compare
WPS21-063UF
Double stage RO ultrapure Water System
Feed Water Requirements*: Water Inlet:
Tap water: TDS<200 ppm (Extra pretreatment filter is recommended, if TDS>200 ppm)
Feed Water Requirements*: Temperature:
5-45°C
Feed Water Requirements*: Pressure:
1.0-4.0 Kgf/cm²
Flow Procedure**:
PF+AC+RO+RO+(UV)+AC+DI+(UF)+TF
Add to Compare
WPS21-063UL
Double stage RO ultrapure Water System
Feed Water Requirements*: Water Inlet:
Tap water: TDS<200 ppm (Extra pretreatment filter is recommended, if TDS>200 ppm)
Feed Water Requirements*: Temperature:
5-45°C
Feed Water Requirements*: Pressure:
1.0-4.0 Kgf/cm²
Flow Procedure**:
PF+AC+RO+RO+(UV)+AC+DI+(UF)+TF
Add to Compare
WPS21-063UV
Double stage RO ultrapure Water System
Feed Water Requirements*: Water Inlet:
Tap water: TDS<200 ppm (Extra pretreatment filter is recommended, if TDS>200 ppm)
Feed Water Requirements*: Temperature:
5-45°C
Feed Water Requirements*: Pressure:
1.0-4.0 Kgf/cm²
Flow Procedure**:
PF+AC+RO+RO+(UV)+AC+DI+(UF)+TF
Add to Compare
WPS21-094
Double stage RO ultrapure Water System
Feed Water Requirements*: Water Inlet:
Tap water: TDS<200 ppm (Extra pretreatment filter is recommended, if TDS>200 ppm)
Feed Water Requirements*: Temperature:
5-45°C
Feed Water Requirements*: Pressure:
1.0-4.0 Kgf/cm²
Flow Procedure**:
PF+AC+RO+RO+(UV)+AC+DI+(UF)+TF
Add to Compare
WPS21-094UF
Double stage RO ultrapure Water System
Feed Water Requirements*: Water Inlet:
Tap water: TDS<200 ppm (Extra pretreatment filter is recommended, if TDS>200 ppm)
Feed Water Requirements*: Temperature:
5-45°C
Feed Water Requirements*: Pressure:
1.0-4.0 Kgf/cm²
Flow Procedure**:
PF+AC+RO+RO+(UV)+AC+DI+(UF)+TF
Add to Compare
WPS21-094UV
Double stage RO ultrapure Water System
Feed Water Requirements*: Water Inlet:
Tap water: TDS<200 ppm (Extra pretreatment filter is recommended, if TDS>200 ppm)
Feed Water Requirements*: Temperature:
5-45°C
Feed Water Requirements*: Pressure:
1.0-4.0 Kgf/cm²
Flow Procedure**:
PF+AC+RO+RO+(UV)+AC+DI+(UF)+TF
Add to Compare
WPS21-094UVF
Double stage RO ultrapure Water System
Feed Water Requirements*: Water Inlet:
Tap water: TDS<200 ppm (Extra pretreatment filter is recommended, if TDS>200 ppm)
Feed Water Requirements*: Temperature:
5-45°C
Feed Water Requirements*: Pressure:
1.0-4.0 Kgf/cm²
Flow Procedure**:
PF+AC+RO+RO+(UV)+AC+DI+(UF)+TF
Add to Compare
WPS21-125
Double stage RO ultrapure Water System
Feed Water Requirements*: Water Inlet:
Tap water: TDS<200 ppm (Extra pretreatment filter is recommended, if TDS>200 ppm)
Feed Water Requirements*: Temperature:
5-45°C
Feed Water Requirements*: Pressure:
1.0-4.0 Kgf/cm²
Flow Procedure**:
PF+AC+RO+RO+(UV)+AC+DI+(UF)+TF
Add to Compare
WPS21-125UF
Double stage RO ultrapure Water System
Feed Water Requirements*: Water Inlet:
Tap water: TDS<200 ppm (Extra pretreatment filter is recommended, if TDS>200 ppm)
Feed Water Requirements*: Temperature:
5-45°C
Feed Water Requirements*: Pressure:
1.0-4.0 Kgf/cm²
Flow Procedure**:
PF+AC+RO+RO+(UV)+AC+DI+(UF)+TF
Add to Compare
WPS21-125UV
Double stage RO ultrapure Water System
Feed Water Requirements*: Water Inlet:
Tap water: TDS<200 ppm (Extra pretreatment filter is recommended, if TDS>200 ppm)
Feed Water Requirements*: Temperature:
5-45°C
Feed Water Requirements*: Pressure:
1.0-4.0 Kgf/cm²
Flow Procedure**:
PF+AC+RO+RO+(UV)+AC+DI+(UF)+TF
Add to Compare
WPS21-125UVF
Double stage RO ultrapure Water System
Feed Water Requirements*: Water Inlet:
Tap water: TDS<200 ppm (Extra pretreatment filter is recommended, if TDS>200 ppm)
Feed Water Requirements*: Temperature:
5-45°C
Feed Water Requirements*: Pressure:
1.0-4.0 Kgf/cm²
Flow Procedure**:
PF+AC+RO+RO+(UV)+AC+DI+(UF)+TF
Add to Compare
WPS55-250
Large Capacity RO Water System
Feed Water Requirements*: Water Inlet:
Tap water or ground water
Flow Procedure**:
QZ+AC+SI+MF+RO
Ion rejection rate:
≥98%
Output(25°C)****:
250 L/hr
Add to Compare
WPS55-500
Large Capacity RO Water System
Feed Water Requirements*: Water Inlet:
Tap water or ground water
Flow Procedure**:
QZ+AC+SI+MF+RO
Ion rejection rate:
≥98%
Output(25°C)****:
500 L/hr
Add to Compare
AIP11-0600
Dispensing Booth
Clean Level:
ISO 5 (Class 100), Class A
HEPA Filters:
99.999% efficiency at 0.3pm
Air volume:
Supply air volume: ≤7500m3/h, Exhaust air volume: ≤2250m3/h; Adjustable
Material:
Fully stainless steel
Add to Compare
AIP11-1000
Dispensing Booth
Clean Level:
ISO 5 (Class 100), Class A
HEPA Filters:
99.999% efficiency at 0.3pm
Air volume:
Supply air volume: ≤7500m3/h, Exhaust air volume: ≤2250m3/h; Adjustable
Material:
Fully stainless steel
Add to Compare
AIP11-1700
Dispensing Booth
Clean Level:
ISO 5 (Class 100), Class A
HEPA Filters:
99.999% efficiency at 0.3pm
Air volume:
Supply air volume: ≤7500m3/h, Exhaust air volume: ≤2250m3/h; Adjustable
Material:
Fully stainless steel
Add to Compare
AIP21-2000
Clean Booth
Clean Level:
ISO 5(Class100),Class A
HEPA Filter:
99.999% efficiency at 0.3pm
FFU Nos.:
4 pcs
Control System:
Microprocessor control system
Add to Compare
AIP21-3000
Clean Booth
Clean Level:
ISO 5(Class100),Class A
HEPA Filter:
99.999% efficiency at 0.3pm
FFU Nos.:
6 pcs
Control System:
Microprocessor control system
Add to Compare
AIP21-4000
Clean Booth
Clean Level:
ISO 5(Class100),Class A
HEPA Filter:
99.999% efficiency at 0.3pm
FFU Nos.:
12 pcs
Control System:
Microprocessor control system
Add to Compare
AIP21-5000
Clean Booth
Clean Level:
ISO 5(Class100),Class A
HEPA Filter:
99.999% efficiency at 0.3pm
FFU Nos.:
25 pcs
Control System:
Microprocessor control system
Add to Compare
AIP31-1000
Pathology Workstation
Work Surface Height:
850 mm
Exhaust Airflow Volume:
500~600m3/h
Main Body Material:
304 stainless steel
Work Table Material:
304 stainless steel
Add to Compare
AIP31-1500
Pathology Workstation
Work Surface Height:
850 mm
Exhaust Airflow Volume:
500~600m3/h
Main Body Material:
304 stainless steel
Work Table Material:
304 stainless steel
Add to Compare
AIP31-1800
Pathology Workstation
Work Surface Height:
850 mm
Exhaust Airflow Volume:
500~600m3/h
Main Body Material:
304 stainless steel
Work Table Material:
304 stainless steel
Add to Compare
AIP41-900
Air Sterilizer
Filter:
Primary Filter, HEPA filter
HEPA Filter:
99.99% efficiency at 0.3pm
UV Lamp:
Germicidal UV lamp, Emission of 253.7 nanometers for most efficient decontamination
Optimal Space:
≤20m2
Add to Compare
AIP51-900
PP Reagent Cabinet
Power Supply:
AC110/220V士10%, 50/60Hz
Package Size (WxDxH):
985x535x1915mm
Gross Weight:
72 kg
External Size (WxDxH):
900x450x1800 mm (can be customized according to customer needs)
Add to Compare
AIP61-070
Ozone UV Sterilization Cabinet
Capacity:
70 L
Sterlization Method:
Ozone
Shelves:
2pcs, optional 2pcs ,adjustable
Work zone Material:
304 stainless steel, 1.0mm thick
Add to Compare
AIP61-090
Ozone UV Sterilization Cabinet
Capacity:
90 L
Sterlization Method:
Ozone
Shelves:
2pcs, optional 2pcs ,adjustable
Work zone Material:
304 stainless steel, 1.0mm thick
Add to Compare
AIP71-O253
UV Sterilization Cabinet
Type:
With Ozone
UV Ray Wavelength:
253.7/184.9nm
Sterilization Way:
2 sides of UV ray+1 side of Ozone
Capacity:
200 L
Add to Compare
AIP71-W253
UV Sterilization Cabinet
Type:
Without Ozone
UV Ray Wavelength:
253.7nm
Sterilization Way:
3 sides of UV ray
Capacity:
200 L
Add to Compare
ANA61-05A
Electrolyte Analyzer
Type:
Automatic
Test Items:
K, Na, Cl, Ca, pH
Test Method:
ISE Direct Method
Test Time:
≤60S
Add to Compare
ANA61-06A
Electrolyte Analyzer
Type:
Automatic
Test Items:
K, Na, Cl, Ca, pH, TCO2
Test Method:
ISE Direct Method
Test Time:
≤60S
Add to Compare
ANA61-03SA
Electrolyte Analyzer
Type:
Semi-automatic
Test Items:
K, Na, Cl
Test Method:
ISE Direct Method
Test Time:
≤60S
Add to Compare
ANA61-05SA
Electrolyte Analyzer
Type:
Semi-automatic
Test Items:
K, Na, Cl, Ca, pH
Test Method:
ISE Direct Method
Test Time:
≤60S
Add to Compare
ANA57-37SP
Auto Chemistry Analyzer
Overall Performance: Throughput:
200 Tests/hour
Overall Performance: Analysis Method:
End-point, Fixed-time, Rate(Kinetic)
Overall Performance: Certificates:
CE, FDA, ISO9001, IS013485
Sample & Reagent System: Sample Positions:
37 sample positions
Add to Compare
ANA57-49SP
Auto Chemistry Analyzer
Overall Performance: Throughput:
200 Tests/hour
Overall Performance: Analysis Method:
End-point, Fixed-time, Rate(Kinetic)
Overall Performance: Certificates:
CE, FDA, ISO9001, IS013485
Sample & Reagent System: Sample Positions:
49 sample positions
Add to Compare
ANA57-60SP
Auto Chemistry Analyzer
Overall Performance: Throughput:
400 Tests/hour
Overall Performance: Analysis Method:
End-point, Fixed-time, Rate(Kinetic)
Overall Performance: Certificates:
CE, FDA, ISO9001, IS013485
Sample & Reagent System: Sample Positions:
60 or 90 sample positions, built-in barcode system available
Add to Compare
ANA57-90SP
Auto Chemistry Analyzer
Overall Performance: Throughput:
600 Tests/hour
Overall Performance: Analysis Method:
End-point, Fixed-time, Rate(Kinetic)
Overall Performance: Certificates:
CE, FDA, ISO9001, IS013485
Sample & Reagent System: Sample Positions:
90 sample positions, built-in barcode system available
Add to Compare
ANA57-150SP
Auto Chemistry Analyzer
Overall Performance: Throughput:
800 Tests/hour, 1200Tests/hour with ISE(Optional)
Overall Performance: Analysis Method:
End-point, Fixed-time, Rate(Kinetic)
Overall Performance: Certificates:
CE, FDA, ISO9001, IS013485
Sample & Reagent System: Sample Positions:
150 sample positions
Add to Compare
ANA60-10IP
Fluorescence Immunoassay Analyzer
Excitation Light Source:
LED
Wavelength:
Excitation Wavelength λo = 365 nm Detection Wavelength- λ₁ = 615 nm
Detection Channel:
1
Incubation Position:
10
Add to Compare
ANA62-80
Automatic ESR Analyzer
Measurement Method:
Infrared detection
Analysis Result:
Westergren ESR value (mm/hour)
Throughput:
Maximum 80 tests/hour
Analysis Channels:
40 (load up to 40 samples for analysis at the same time)
Add to Compare
BAC81-200
Water Bath
Capacity:
10 L
Temp. Control Range:
R.T.+5°C ~100°C
Temp.Stability(100°C):
±0.5°C
Time Range:
1m~99h59m OFF is forever
Add to Compare
BAC81-700
Water Bath
Time Range:
1~99h59min (0 is forever)
Temperature Range:
RT.+5°C~100°C
Temp. accuracy:
±0.5°C
Temp. Uniformity@37°C:
±0.5°C
Add to Compare
BAC81-300
Water Bath
Time Range:
1~99h59min (0 is forever)
Temperature Range:
RT.+5°C~100°C
Temp. accuracy:
±0.5°C
Temp. Uniformity@37°C:
±0.5°C
Add to Compare
BAC81-600
Water Bath
Time Range:
1~99h59min (0 is forever)
Temperature Range:
RT.+5°C~100°C
Temp. accuracy:
±0.5°C
Temp. Uniformity@37°C:
±0.5°C
Add to Compare
BAC81-900
Water Bath
Time Range:
1~99h59min (0 is forever)
Temperature Range:
RT.+5°C~100°C
Temp. accuracy:
±0.5°C
Temp. Uniformity@37°C:
±0.5°C
Add to Compare
BAC34-110HC
Dual Temperature Control Dry Bath Incubator
Temperature Range:
Heating: Room temp.-110°C Cooling: Room temp.~below room temp. 25°C
Temperature Uniformity:
Max. ±0.5°C(@20°C-25°C)
Outer Dimension (WxDxH):
200Wx235Dx120H mm
Weight:
7.3 kg
Add to Compare
BAC1A-02
Micro-plate Incubator
Temp. Control Range:
R.T.+5°C ~70°C
Temp. Setting Range:
5°C ~70°C
Temp. Stability@37°C:
±0.2°C
Platform Temp. Uniformity:
±0.5°C
Add to Compare
BAC1A-04
Micro-plate Incubator
Temp. Control Range:
R.T.+5°C ~70°C
Temp. Setting Range:
5°C ~70°C
Temp. Stability@37°C:
±0.2°C
Platform Temp. Uniformity:
±0.5°C
Add to Compare
BAC31-100RT
Dual Temperature Control Dry Bath Incubator
Temperature Range:
R.T.+5 °C~105 °C
Temp. Setting Range:
5°C~105°C
Temperature Stability@100°C:
±0.5°C
Temperature Stability@40°C:
0.3 °C
Add to Compare
BAC32-100HC
Dual Temperature Control Dry Bath Incubator
Temperature Range:
Heating: R.T.+5°C~105°C and Cooling: -10°C~105°C
Temp. Setting Range:
Heating:5 °C ~105 °C, Cooling:-10 °C ~105 °C
Temperature Max. Decrease:
Cooling: R.T. decreases @R.T. 26°C
Temperature Stability@100°C:
±0.5 °C
Add to Compare
BAC35-100
Dual Temperature Control Dry Bath Incubator
Temperature Range:
0-100 °C
Temp. Setting Range:
±0.5 °C
Weight:
1.4 kg
Temperature Precision:
±0.5°C
Add to Compare
BAC36-100
Dual Temperature Control Dry Bath Incubator
Temperature Range:
0-100 °C
Temperature Uniformity:
±0.5 °C
Weight:
1.4 kg
Temperature Precision:
±0.5°C
Add to Compare
BAC33-100C
Dual Temperature Control Dry Bath Incubator
Temperature Range:
-10°C~105°C
Temp. Setting Range:
-10°C~105°C
Temperature Max. Decrease:
R.T. decreases 25°C@R.T. 26°C
Temperature Stability@100°C:
±0.5°C
Add to Compare
BAC36-100PS
Dual Temperature Control Dry Bath Incubator
Temperature Range:
0-100°C Programmable 3 segments
Outer Dimension (WxDxH):
185x185x90 mm
Weight:
1.4 kg
Temperature Precision:
±0.5°C
Add to Compare
BAC44-100RT
Dual Temperature Control Dry Bath
Temperature Range:
4-100°C
Temperature Uniformity:
±0.5°C
Outer Dimension (WxDxH):
130x130x85 mm
Weight:
0.75 kg
Add to Compare
BAC028-05
Water Bath
Capacity:
5 L
Power requirements:
AC 220 V 50 HZ
Power:
500 W
Temperature Range:
RT+5 - 100°C
Add to Compare
BAC028-12
Water Bath
Capacity:
12 L
Power requirements:
AC 220 V 50 HZ
Power:
800 W
Temperature Range:
RT+5 - 100°C
Add to Compare
BAC028-22A
Water Bath
Capacity:
22 L
Power requirements:
AC 220 V 50 HZ
Power:
1000 W
Temperature Range:
RT+5 - 100°C
Add to Compare
BAC028-22B
Water Bath
Capacity:
22 L
Power requirements:
AC 220 V 50 HZ
Power:
1000 W
Temperature Range:
RT+5 - 80°C
Add to Compare
BAC031-33
Shaking Water Bath
Capacity:
33 L
Temperature range:
RT+5 - 99°C
Display resolution:
0.1°C
Temperature uniformity (at 37°C):
±1.0°C
Add to Compare
BAC031-47
Shaking Water Bath
Capacity:
47 L
Temperature range:
RT+5 - 99°C
Display resolution:
0.1°C
Temperature uniformity (at 37°C):
±1.0°C
Add to Compare
BAC034-33A
Shaking Water Bath
Capacity:
33 L
Temperature range:
RT+5-100°C
Display Resolution:
0.1°C
Temperature Uniformity:
±1°C
Add to Compare
BAC034-33B
Shaking Water Bath
Capacity:
33 L
Temperature range:
RT+5-100°C
Display Resolution:
0.1°C
Temperature Uniformity:
±1°C
Add to Compare
BAC034-47A
Shaking Water Bath
Capacity:
47 L
Temperature range:
RT+5-100°C
Display Resolution:
0.1°C
Temperature Uniformity:
±1°C
Add to Compare